Penta Series with Video Process-CNC – Instruction Manual – Edition 05-1985
Hydraulic and Electrical Adjustments – Section III
Abbreviated setup notes taken from manual.
Do Not exceed 12V output when setting Max-Min trimmers.
Before VP2 (proportional valve), set min-max voltages of VP6 (proportional valve).
VP6 – Flow Calibration – 3.10
Card 30 - meter 71-70 (top) - RV1 mould sensing, RV3 max speed, RV4 min speed
- Final Braking Speed
- when mold opening (P2 pressed) adjust RV1 for smooth travel – Note avoid sharp mold movement
- min flow level calibration (speed)
- when mold closing (P1 pressed) adjust RV4 for approx 4V
- when mold closed – does toggle crosshead stay put (toggle fully extended), no opening begins
- increase RV4 to see if opening starts
- decrease RV4 until crosshead locked
- max flow level calibration (speed)
- view page-02
- CONSTANT SPEED OPENING = YES
- MOLD OPENING STROKE = set for machine type spec)
- SPEED 1-3 STAGE OPENING = 50%
- FINAL OPENING BREAKING SPEED = 99%
- open mold (press P2) – LED stays on ??
- no : reduce stroke of mold jack (RLC device, code 035) until P2 LED lights
- adjust RV3 for 7.2V
- view page-02
VP2 – Flow Calibration
Hydraulic Calibration
- remove coil VP2 from solenoid
- on manual, close then open mold – watch both movements
- if smooth (no pulsation), calibration is correct or high
- adjust spindle (fig 3-2, detail 1, under nut-cap), anti-clockwise 1-deg at a time, repeating open-close cycle, for lowest speed without pulsation.
- if pulsating, rotate spindle clockwise 1-deg at a time
- lock spindle, replace cap
- replace coil VP2 on solenoid
Electrical Calibration – 3.2.2.
Card 29 - meter 62-61 (top) - RV3 max flow, RV4 min flow
- Minimum speed level calibration – 3.2.2.1
- view page-02
- BREAKING THROUGHOUT THE STROKE = YES
- view page-03
- SET MAXIMUM MOLD PRESSURE TO CLOSE TOGGLE : for machine type ???
- on manual, open the mold
- adjust RV4 for approx 2.5V (while open/close active)
- view page-02
- BREAKING THROUGHOUT THE STROKE = YES
- CONSTANT SPEED CLOSING = YES
- CONSTANT SPEED OPENING = YES
- SPEED 1-3 stage closing = 15%
- SPEED 1-3 stage opening = 15%
- on manual, close and open mold looking for noticeable variation in speed
- if yes, min speed level calibration is valid
- if no, voltage low, increase RV4 until there is a noticeable variation
- Maximum speed level calibration – 3.3.3.2
- Note: MUST BE MATERIAL IN THE HOPPER
- view page-08
- SCREW ROTATION WITH 2 PUMPS = NO
- view page-02
- SLOW SPEED COMPLETE STROKE = YES
- view page-10
- SPEED-VI = 99%
- on manual close mold then screw rotation (pressing P1 and P4) – maintain during calibration
- adjust RV3 (still on card 29) for maximum screw rotations – likely approx. 5V
- check if number of screw rotations varies with speed setting
- view page-10
- change SPEED-VI = from 99% to 95%
- press screw rotation button P4
- does screw rotations decrease
- if no, max set too high so decrease V with RV3
- does screw rotations decrease
- view page-10
- NOTE: screw rotation P4 must be cycled after each change to check rotations
Pressure Control – VP1 – 3.4
- Hydraulic Calibration
- Ensure maximum hydraulic pressure – 3.4.1
- remove cap – loosen locknut – seat spindle – lock locknut
- Electrical Calibration – 3.4.2.1 – Card 29 – meter 60-61 (bottom)
- see pressure chart bottom of page 3-3
- Minimum pressure level calibration
- view page-03
- HIGH PRESSURE LOCKING = (min mm from bottom of page-03 under “position, high press from…to…mm”)
- on manual close mold – hold P1 during whole calibration operation
- adjust RV8 (min level), V approx 1V
- view page-03
- HIGH PRESSURE = at least 10 Bar higher than machine min setting
- on manual mold closing – button P1
- pressure gauge P1 on the gauge – check level
- adjust RV8 until gauge shows page-03 HIGH PRESSURE
- if no change when page-03 setting changed
- adjust RV7 to reduce voltage on meter
- NOTE: mold closing P1 must be cycled after each change to check pressure
Electrical calibration can be considered complete – go to “Final Hydraulic Calibration”
- Maximum pressure level calibration
Final Hydraulic Calibration – 3.5
- view page-03
- HIGH PRESSURE = (max value (MAX….BAR)
- set pressure gauge to position P1
- on manual close mold (pressing P1) watching pressure
- remove cap, loosen locknut – fig. 3-4 detail-1
- turn spindle anti-clockwise for reading approx 10 bar below working pressure
- turn spindle clockwise to working pressure
- lock spindle and replace cap
Flow Calibration – VP4 – 3.6
Electrical Calibration
Card-31 - meter 64-65 (top) - RV3 max flow RV4 min flow
- Minimum speed level calibration – 3.6.1.1
- Maximum speed level calibration – 3.6.1.2
Pressure Calibration – VP3 – 3.7
Hydraulic Calibration
Electrical Calibration
- Min pressure level calibration – 3.7.2.1
- Max pressure level calibration – 3.7.2.2
Final Hydraulic Calibration – 3.8
.
Flow Calibration – 3.10
See beginning of Section 3. This is done first.
Moog Valve Calibration – VP5 – 3.11 replaces 3.9
Card-33 and 33 - meter 64-65 (top) - RV3 max flow RV4 min flow
- Supply voltages on back of Card-32 and Card-33 must be within spec. (manual page 3.9) – 3.11.1
- Servovalve zero calibration – 3.11.2
- Check of the suck-back signal – 3.11.3
- Check of the speed setting – 3.11.4
- Check of the real injection speed – 3.11.5
- Check of the hold pressure – 3.11.6
- Calibration of CPO-CPC transducers – 3.11.7
- Check of hold pressure – 3.11.8
- Check of screw back pressure – 3.11.9
Calibration of Injection Carriage Transducer – 3.12
.
Calibration of Hydraulic Ejector Position Transducer – 3.13
.
Calibration of Mould Position Transducer – 3.14
.
Calibration of Injection Axes Position Transducer – 3.15
.
Calibration of Hydraulic Pressure Transducer (CPO) – 3.16
.
Calibration of Cavity Ppressure Transducer (CPC) – 3.17
.
Temperature Controller Calibration – 3.18
.